Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32.360
Filtrar
Mais filtros











Intervalo de ano de publicação
2.
J Orthop Surg Res ; 19(1): 261, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659063

RESUMO

PURPOSE: The aim of this study was to investigate the clinical efficacy of full endoscopic lumbar annulus fibrosus suture in the treatment of single-segment lumbar disc herniation (LDH). METHODS: The clinical data of patients with single-segment LDH who underwent full endoscopic lumbar discectomy from January 2017 to January 2019 in our hospital were retrospectively analysed. Patients with full endoscopic lumbar discectomy combined with annulus fibrosus suture were divided into group A, and those with simple full endoscopic lumbar discectomy were divided into group B. The general information, surgery-related data, visual analog scale (VAS), Oswestry disability index (ODI), modified MacNab score at the last follow-up, reoperation rate and recurrence were compared between the two groups. RESULTS: All patients were followed up for 12 to 24 months, and the surgical time was 133.6 ± 9.6 min in group A and 129.0 ± 11.7 min in group B. The difference was not statistically significant (p > 0.05). The blood loss of group A was higher than that of group B, and the difference was statistically significant when comparing the groups (p < 0.05). The postoperative symptoms of patients in both groups were significantly relieved, and the VAS score of low back pain and ODI index were significantly lower than the preoperative ones at all postoperative time points (1 month after surgery, 3 months after surgery, and at the last follow-up) (p < 0.05), but there was no significant difference between the groups (p > 0.05). The excellent rate of MacNab at the last follow-up in the two groups were 93.55% and 87.80%, respectively, with no statistically significant difference (p > 0.05). At the last follow-up, the recurrence rate of group A was significantly lower than that of group B, and the difference was statistically significant (p < 0.05), while the difference between the reoperation rate of the two groups was not statistically significant (p > 0.05). CONCLUSIONS: Full endoscopic lumbar discectomy combined with annulus fibrosus repair reduces the postoperative recurrence rate and achieves satisfactory clinical outcomes.


Assuntos
Anel Fibroso , Endoscopia , Deslocamento do Disco Intervertebral , Vértebras Lombares , Humanos , Masculino , Feminino , Vértebras Lombares/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Endoscopia/métodos , Anel Fibroso/cirurgia , Resultado do Tratamento , Seguimentos , Técnicas de Sutura , Discotomia/métodos
3.
Innovations (Phila) ; 19(2): 196-203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38576096

RESUMO

In the evolving landscape of cardiac surgery, this article explores the potential of minimally invasive mitral valve replacement procedures as a viable alternative to conventional surgical techniques. Leveraging advancements in automated suturing devices and video endoscopy, our work aims to demonstrate that minimally invasive approaches can be applied across a broad spectrum of surgical scenarios. Herein we highlight preoperative diagnostics and operative techniques, with a focus on infra-axillary anterolateral minithoracotomy as the access point. Our technique utilizes technology from LSI SOLUTIONS® (Victor, NY, USA), including the RAM® Device for automated suturing, which has an ergonomic design and safety features. The device's capabilities are further enhanced by the SEW-EASY® Device, the RAM® RING, and the COR-KNOT MINI® Device, which streamline suture management and securement. This work outlines how these technological advancements can mitigate concerns about technical complexity and learning curves, thereby encouraging wider adoption of minimally invasive techniques. Clinical benefits may include reduced surgical trauma, quicker recovery, and cost-effectiveness, making it a compelling option in an era of aggressively promoted transcatheter interventions.


Assuntos
Endoscopia , Implante de Prótese de Valva Cardíaca , Procedimentos Cirúrgicos Minimamente Invasivos , Valva Mitral , Técnicas de Sutura , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Técnicas de Sutura/instrumentação , Endoscopia/métodos , Endoscopia/instrumentação , Toracotomia/métodos
5.
Ann Plast Surg ; 92(4S Suppl 2): S150-S155, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556665

RESUMO

BACKGROUND: Use of the absorbable deep dermal stapler in wound closure has become more common in plastic surgery because of its possible reduction in operative times and subsequent decrease in operative room costs. In this study, we examine the effects of this stapler on operative times and postoperative complications in bilateral reduction mammaplasties. METHODS: A retrospective, observational cohort study was conducted via electronic chart review on patients who underwent bilateral reduction mammaplasties. Patients were stratified by wound closure method. One group was closed with sutures only, and in the other group, deep dermal staples were used during closure of the inframammary fold incision. Incidences of patient comorbidities and postoperative complications were compared. In addition, a financial cost analysis was performed. RESULTS: The final patient cohort included 62 patients. Operative time was reduced by an average of 21.8 minutes when using deep dermal staples during closure, compared with when closing solely with sutures (P = 0.032). When controlling for mass of breast tissue removed and type of pedicle, deep dermal staple closure still predicted a reduction of 26.5 (SE, 9.9) minutes in operative time (P = 0.010). Postoperative complications were not affected by wound closure method (odds ratio, 4.36; 95% confidence interval, 0.91-31.7, P = 0.087). Though not statistically significant, financial charge was decreased with usage of deep dermal staples (P = 0.34). CONCLUSIONS: Use of absorbable deep dermal staples produces a significant decrease in operative time for reduction mammaplasties with no increase in postoperative complication rates.


Assuntos
Mamoplastia , Técnicas de Sutura , Humanos , Mamoplastia/efeitos adversos , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/etiologia , Suturas/efeitos adversos , Resultado do Tratamento , Feminino
6.
J Cardiothorac Surg ; 19(1): 174, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576006

RESUMO

BACKGROUND: There is ambiguity in the literature regarding the continuous suture technique (CST) for aortic valve replacement (AVR). At our center, there has been a gradual shift towards CST over the interrupted pledgeted technique (IPT). This study aims at comparing outcomes for both techniques. METHODS: We performed a retrospective analysis of a single-center study of patients undergoing AVR between January 2011 and July 2020. Patients were divided into two groups: Continuous suture technique and interrupted pledget-reinforced sutures. The pre-operative and In-hospital clinical characteristics and echocardiographic hemodynamics (i.e. transvalvular gradients and paravalvular leakage) were compared between CST and IPT. RESULTS: We compared 791 patients with CST to 568 patients with IPT (median age: 73 and 74 years, respectively, p = 0.02). In CST there were 35% concomitant procedure vs. 31% in IPT (p = 0.16). Early mortality was 3.2% in CST versus 4.8% in IPT (p = 0.15), and a second cross-clamp due to a paravalvular-leak in 0.5% vs. 1.2%, respectively (p = 0.22). The CST was not associated with new-onset conduction-blocks mandating pacemaker implants(OR 1.07, 95% CI 0.54-2.14; P = 0.85). The postoperative gradients on echocardiography were lower in CST compared to IPT, especially in smaller annuli (peak gradients: 15.7mmHg vs. 20.5mmHg, in valve size < 23 mm, p < 0.001). CONCLUSIONS: The continuous suture technique was associated with lower postoperative gradients and shorter cross-clamp time compared to interrupted pledgeted technique. Differences in paravalvular leaks were non-significant, although slightly less in the continuous suture technique. There were no further differences in valve-related complications. Hence, continues suture technique is safe, with better hemodynamics compared to the interrupted pledgeted technique. This may be of clinical importance, especially in smaller size annular size.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Técnicas de Sutura , Resultado do Tratamento , Desenho de Prótese
8.
BMC Surg ; 24(1): 123, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658911

RESUMO

OBJECTIVE: This study introduced the modified Q-type purse-string suture duodenal stump embedding method, a convenient way to strengthen the duodenum, and compared it to the conventional one to assess its efficacy and safety. METHODS: This retrospective analysis examined 612 patients who received laparoscopic gastrectomy for gastric Cancer at a single center. The patients were divided into Not Reinforced Group (n = 205) and Reinforced Group (n = 407) according to the surgical approach to the duodenal stump. The reinforced group was further divided into a modified Q-type purse-string suture embedding method group (QM, n = 232) and a conventional suture duodenal stump embedding method group (CM, n = 175) according to the methods of duodenal stump enhancement. Clinicopathological characteristics, operative variables, and short-term complications were documented and analyzed. RESULTS: The incidence of duodenal stump leakage(DSL) in the Not Reinforced Group was higher compared to the Reinforced Group, although the difference was not statistically significant [2.4% (5/205) vs 0.7% (3/407), p = 0.339]. Additionally, the Not Reinforced Group exhibited a higher rate of Reoperation due to DSL compared to the Reinforced Group [2 (1.0%) vs. 0, p = 0.046], with one patient in the Not Reinforced Group experiencing mortality due to DSL [1 (0.5%) vs 0, p = 0.158]. Subgroup analysis within the Reinforced Group revealed that the modified Q-type purse-string suture embedding group (QM) subgroup demonstrated statistically significant advantages over the conventional suture embedding group (CM) subgroup. QM exhibited shorter purse-string closure times (4.11 ± 1.840 vs. 6.05 ± 1.577, p = 0.001), higher purse-string closure success rates (93.1% vs. 77.7%, p = 0.001), and greater satisfaction with purse-string closure [224 (96.6%) vs 157 (89.7%), p = 0.005]. No occurrences of duodenal stump leakage were observed in the QM subgroup, while the CM subgroup experienced two cases [2 (1.1%)], though the difference was not statistically significant. Both groups did not exhibit statistically significant differences in secondary surgery or mortality related to duodenal stump leakage. CONCLUSION: Duodenal Stump Leakage (DSL) is a severe but low-incidence complication. There is no statistically significant relationship between the reinforcement of the duodenal stump and the incidence of DSL. However, laparoscopic reinforcement of the duodenal stump can reduce the severity of fistulas and the probability of Reoperation. The laparoscopic Q-type purse-string suture duodenal stump embedding method is a simple and effective technique that can, to some extent, shorten the operation time and enhance satisfaction with purse-string closure. There is a trend towards reducing the incidence of DSL, thereby improving patient prognosis to a certain extent.


Assuntos
Duodeno , Gastrectomia , Laparoscopia , Neoplasias Gástricas , Técnicas de Sutura , Humanos , Gastrectomia/métodos , Laparoscopia/métodos , Neoplasias Gástricas/cirurgia , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Idoso , Duodeno/cirurgia , Resultado do Tratamento , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
9.
Langenbecks Arch Surg ; 409(1): 124, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615148

RESUMO

PURPOSE: Gastrointestinal disorders frequently necessitate surgery involving intestinal resection and anastomosis formation, potentially leading to severe complications like anastomotic leakage (AL) which is associated with increased morbidity, mortality, and adverse oncologic outcomes. While extensive research has explored the biology of anastomotic healing, there is limited understanding of the biomechanical properties of gastrointestinal anastomoses, which was aimed to be unraveled in this study. METHODS: An ex-vivo model was developed for the biomechanical analysis of 32 handsewn porcine end-to-end anastomoses, using interrupted and continuous suture techniques subjected to different flow models. While multiple cameras captured different angles of the anastomosis, comprehensive data recording of pressure, time, and temperature was performed simultaneously. Special focus was laid on monitoring time, location and pressure of anastomotic leakage (LP) and bursting pressures (BP) depending on suture techniques and flow models. RESULTS: Significant differences in LP, BP, and time intervals were observed based on the flow model but not on the suture techniques applied. Interestingly, anastomoses at the insertion site of the mesentery exhibited significantly higher rates of leakage and bursting compared to other sections of the anastomosis. CONCLUSION: The developed ex-vivo model facilitated comparable, reproducible, and user-independent biomechanical analyses. Assessing biomechanical properties of anastomoses offers an advantage in identifying technical weak points to refine surgical techniques, potentially reducing complications like AL. The results indicate that mesenteric insertion serves as a potential weak spot for AL, warranting further investigations and refinements in surgical techniques to optimize outcomes in this critical area of anastomotic procedures.


Assuntos
Fístula Anastomótica , Mesentério , Animais , Suínos , Fístula Anastomótica/prevenção & controle , Anastomose Cirúrgica , Mesentério/cirurgia , Técnicas de Sutura , Cicatrização
10.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651698

RESUMO

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Esclera/cirurgia , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia , Retalhos Cirúrgicos , Técnicas de Sutura , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia
12.
BMC Surg ; 24(1): 119, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654240

RESUMO

PURPOSE: To investigate the application and effectiveness of tension-reducing suture in the repair of hypertrophic scars. METHODS: A retrospective analysis of clinical data was conducted on 82 patients with hypertrophic scars treated at the Department of Burns and Plastic Surgery of Nanjing Drum Tower Hospital from September 2021 to December 2022. Patients were operated with combination of heart-shaped tension-reducing suturing technique and looped, broad, and deep buried (LBD) suturing technique or conventional suture method. Outcomes of surgical treatment were assessed before and 6 months after surgery using the Patient and Observer Scar Assessment Scale (POSAS) and the Vancouver Scar Scale (VSS). RESULTS: Improvements were achieved on scar quality compared to that preoperatively, with a reduction in scar width (1.7 ± 0.6 cm vs. 0.7 ± 0.2 cm, P < 0.001). Assessment using the POSAS and VSS scales showed significant improvements in each single parameter and total score compared to preoperative values (P < 0.05). The Combination method group achieved better score in total score of VSS scale, in color, stiffness, thickness and overall opinion of PSAS scale, and in vascularity, thickness, pliability and overall opinion of OSAS scale. CONCLUSION: The amalgamation of the heart-shaped tension-reducing suturing technique and the LBD suturing technique has shown promising outcomes, garnering notably high levels of patient satisfaction in the context of hypertrophic scar repair. Patients have exhibited favorable postoperative recoveries, underscoring the clinical merit and the prospective broader applicability of this approach in the realm of hypertrophic scar management.


Assuntos
Cicatriz Hipertrófica , Técnicas de Sutura , Humanos , Cicatriz Hipertrófica/etiologia , Cicatriz Hipertrófica/prevenção & controle , Estudos Retrospectivos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem , Suturas , Adolescente
13.
Khirurgiia (Mosk) ; (4): 29-37, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634581

RESUMO

OBJECTIVE: To evaluate the short-term outcomes of mechanical and hand-sewn laparoscopic one-anastomosis mini-gastric bypass. MATERIAL AND METHODS: There were 233 patients who underwent laparoscopic one-anastomosis mini-gastric bypass. Short-term results were analyzed in groups of mechanical (the first group, n=108) and hand-sewn (the second group, n=125) gastrojejunostomy. No significant between-group differences in baseline data were detected (demographic characteristics, body mass index, comorbidity and previous abdominal surgeries). RESULTS: Surgery time and blood loss were similar in both groups. Intraoperative morbidity was 7.2-10.2% (p=0.485). All complications required no surgical conversion (Satava-Kazaryan grade I). Overall postoperative morbidity was 16.0-21.3% (p=0.314). Most events corresponded to Accordion grade I and had no significant effect on hospital-stay. CONCLUSION: This study revealed no significant differences in short-term outcomes after laparoscopic one-anastomosis gastric bypass with mechanical and hand-sewn gastrojejunostomy. Further study of long-term clinical outcomes is necessary.


Assuntos
Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Derivação Gástrica/métodos , Laparoscopia/métodos , Técnicas de Sutura/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
14.
BMC Ophthalmol ; 24(1): 112, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454351

RESUMO

INTRODUCTION: Severe congenital ptosis poses a complex challenge for oculoplastic surgeons, requiring meticulous surgical intervention to restore eyelid function and improve aesthetic outcomes mainly by using frontalis sling approach. A crucial issue in frontalis sling surgeries is the sustainability of effect. PURPOSE: This retrospective study reports the outcomes of two surgical techniques for treating severe congenital ptosis in the paediatric age group: Silicon rods ptosis sling and a novel technique involving the use of Silicon rods with green braided polyester (Ethibond) sutures to secure the rods in place "sling for the sling". METHODS: The medical records of children who underwent frontalis suspension were reviewed in a retrospective fashion. We identified two groups; the first group (20 patients: 35 eyelids) had the traditional frontalis suspension surgery using silicone suspension set, the second group (14 patients: 25 eyelids) was operated using the new "sling for sling" technique. We used the postoperative marginal reflex distance-1 (MRD-1) as the primary outcome measure while the frequency of both wound related complications and recurrence were considered as secondary outcome measures. Post operative data were collected and compared after 1 month, 6 months, 12 months, and 18 months. RESULTS: Preliminary results indicate promising outcomes for both techniques, with significant improvement in eyelid elevation observed in both groups. However, the novel technique using Silicon rods with Ethibond sutures demonstrated enhanced sustainability, leading to a more durable outcome with significantly less recurrence. CONCLUSION: This study highlights the potential benefits of the novel technique in treating severe congenital ptosis and introduces an innovative approach to Silicone rods fixation to achieve a long-term corrective effect.


Assuntos
Blefaroplastia , Blefaroptose , Criança , Humanos , Blefaroplastia/métodos , Estudos Retrospectivos , Silício , Técnicas de Sutura , Blefaroptose/cirurgia , Blefaroptose/congênito , Silicones , Músculos Oculomotores/cirurgia , Resultado do Tratamento
15.
J Gynecol Obstet Hum Reprod ; 53(5): 102758, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38432626

RESUMO

OBJECTIVE: Incomplete healing after cesarean section (CS) can result in isthmocele formation. When suturing the uterus, fully folding the wound lips may embed the endometrial layer into the myometrium, leading to isthmocele development. Hence, this study aimed to compare the effects of endometrial and non-endometrial suturing on isthmocele development. MATERIAL AND METHODS: This randomized controlled trial included 274 patients. Women who underwent primary CS were randomly allocated to one of the two study groups: endometrial suturing and non-endometrial suturing. The primary outcome was isthmocele rate at postpartum 6 months. Secondary outcomes were the volume of the isthmocele, thickness of the residual myometrium, menstrual irregularities (intermenstrual spotting), and the relationship between the isthmocele and uterine position. RESULTS: A total of 159 patients (81 in the endometrial suturing group and 78 in the non-endometrial suturing group) were analyzed. The incidence of isthmocele was significantly lower in the non-endometrial suturing group than in the endometrial suturing group (12 [15.4%] vs. 24 [29.6%] patients; p = 0.032). Menstrual irregularities, such as intermenstrual spotting, were significantly higher in the endometrial suturing group than in the non-endometrial group (p = 0.019). CONCLUSION: Uterine closure with non-endometrial suturing was associated with significantly lower isthmocele development and less intermenstrual spotting compared to that with endometrial suturing.


Assuntos
Cesárea , Endométrio , Técnicas de Sutura , Humanos , Feminino , Cesárea/métodos , Adulto , Endométrio/cirurgia , Útero/cirurgia , Complicações Pós-Operatórias/epidemiologia , Gravidez , Doenças Uterinas/cirurgia , Distúrbios Menstruais/etiologia , Distúrbios Menstruais/cirurgia
17.
Sci Rep ; 14(1): 7289, 2024 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538657

RESUMO

Iatrogenic stomach perforation is a detrimental, irreversible, and fatal condition. Traditional surgery and endoscopic suturing clips and devices have been introduced to seal holes and prevent sepsis and disease progression. However, the development of endoscopic devices for perforations remains challenging, with no standard device available. This study investigates the superficial layer approximation strengths of the newly designed ENDOCRAB system for gastric wall defects. Thirty porcine stomachs were prepared ex vivo for the perforation model and distributed equally into three groups: ENDOCRAB system, Through-the-Scope Clip (TTSC), and hand suturing (HS). Both ENDOCRAB and TTSC achieved mucosal-submucosal layer apposition, whereas HS allowed a full-thickness layer. Their air leakage pressure and procedural duration were measured. The analysis of air-leakage pressure demonstrated comparable suture strength between ENDOCRAB (118.5 ± 41.7 mmHg) and HS (127.4 ± 30.2 mmHg, P = 0.812), but inferior strength with TTSC (73.6 ± 21.6 mmHg, P = 0.012). HS achieved the shortest procedural duration, whereas ENDOCRAB and TTSC showed no significant differences. The ENDOCRAB system showed significantly greater strength than the TTSC, was comparable to HS in strength, and required a procedural duration similar to that of the TTSC. Furthermore, long-term in vivo experiments and histological evaluations are essential.


Assuntos
Cirurgia Endoscópica por Orifício Natural , Gastropatias , Suínos , Animais , Estômago/cirurgia , Técnicas de Sutura , Instrumentos Cirúrgicos
18.
BMC Musculoskelet Disord ; 25(1): 246, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38539131

RESUMO

BACKGROUND: Shoulder disorders, particularly rotator cuff tears, are prevalent musculoskeletal conditions related to aging. Although the widely used suture anchor technique provides strong mechanical support to the tendon, it is associated with a risk of postoperative tendon retearing. The conventionally used titanium alloys can affect the interpretation of magnetic resonance imaging. Degradable magnesium alloys possess excellent biocompatibility, similar mechanical property to the bone, and stimulating bone formation ability from Mg2+. The purpose of this experiment was to develop innovative magnesium-based suture anchors to enhance rotator cuff repair by improving fixation materials, and to evaluate their feasibility in a goat model. METHODS: We developed fluoridized ZK60 suture anchors as the implantation material for two goats, who underwent rotator cuff repair surgery on both shoulders. Computed tomography (CT) and histological analysis were performed at 12 weeks postoperatively, and the results were compared between the magnesium and titanium alloy groups. Additionally, a hematological examination was conducted, which included assessments of red blood cells, white blood cells, platelets, coagulation function, liver function, kidney function, and magnesium ion concentration. RESULTS: The 12-week postoperative CT images showed intact MgF2 ZK60 suture anchors, effectively reconnecting the infraspinatus tendon to the humeral head. The anchors became less visible on CT scans, indicating absorption by surrounding tissues. New bone formation in the MgF2 group surpassed that in the Ti group, demonstrating superior osseointegration. The similarity between cortical bone and magnesium reduced stress-shielding and promoted bone regeneration. Histological analysis revealed successful tendon healing with MgF2 anchors, while the Ti group showed discontinuous interfaces and reduced collagen secretion. Hematological examination showed stable liver, renal function, and magnesium ion levels. CONCLUSIONS: The findings indicate that MgF2-coated suture anchors are feasible for rotator cuff repair and potentially other orthopedic applications. We hope that magnesium alloy anchors can become the solution for rotator cuff tendon repair surgery.


Assuntos
Lesões do Manguito Rotador , Ombro , Animais , Ombro/cirurgia , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/patologia , Âncoras de Sutura , Magnésio , Cabras , Titânio , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Ligas , Técnicas de Sutura , Artroscopia/métodos
19.
J Cardiothorac Surg ; 19(1): 158, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38539222

RESUMO

BACKGROUND: Functional tricuspid regurgitation may arise from left heart valve diseases or other factors. If not addressed concurrently with primary surgical intervention, it may contribute to increased morbidity and mortality rates during the postoperative period. This study investigates the impact of various repair techniques on crucial factors such as systolic pulmonary artery pressure (SPAP), tricuspid valve regurgitation, and New York Heart Association (NYHA) functional capacity class in the postoperative period. MATERIALS AND METHODS: From April 2007 to June 2013, 379 adults underwent open-heart surgery for functional tricuspid regurgitation. Patients were categorized into four groups: Group 1 (156) with De Vega suture annuloplasty, Group 2 (60) with Kay suture annuloplasty, Group 3 (122) with Flexible Duran ring annuloplasty, and Group 4 (41) with Semi-Rigid Carpentier-Edwards ring annuloplasty. Demographic, clinical, operative, and postoperative data were recorded over a mean follow-up of 35.6 ± 19.1 months. Postoperative SPAP values, tricuspid regurgitation grades, and NYHA functional capacity classes were compared among the groups. RESULTS: No statistically significant differences were observed among the groups regarding age, gender, preoperative disease diagnoses, history of previous cardiac operations, or echocardiographic characteristics such as preoperative ejection fraction, SPAP, and tricuspid regurgitation. Hospital and intensive care unit length of stay and postoperative complications also showed no significant differences. However, patients in Group 3 exhibited longer Cardio-Pulmonary Bypass duration, cross-clamp duration, and higher positive inotrope requirements. While the mortality rate within the first 30 days was higher in Group 1 compared to the other groups (p: 0.011), overall mortality rates did not significantly differ among the groups. Significant regression in functional tricuspid regurgitation and a notable decrease in SPAP values were observed in patients from Group 3 and Group 4 (p: 0.001). Additionally, patients in Group 3 and Group 4 showed a more significant reduction in NYHA functional capacity classification during the postoperative period (p: 0.001). CONCLUSION: Among the repair techniques, ring annuloplasty demonstrated superiority in reducing SPAP, regressing tricuspid regurgitation, and improving NYHA functional capacity in functional tricuspid regurgitation repairs.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Valva Mitral/cirurgia , Técnicas de Sutura
20.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 267-271, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500417

RESUMO

Objective: To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods: A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results: The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores ( P<0.05). Conclusion: Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.


Assuntos
Lesões do Ligamento Cruzado Anterior , Fratura Avulsão , Ligamento Cruzado Posterior , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Ligamento Cruzado Posterior/cirurgia , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Anterior/cirurgia , Fratura Avulsão/cirurgia , Estudos Retrospectivos , Lesões do Ligamento Cruzado Anterior/cirurgia , Resultado do Tratamento , Artroscopia/métodos , Técnicas de Sutura , Articulação do Joelho/cirurgia , Fraturas da Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA